# Complete per-user Windows installer — version21 candidate Run **PlotDirectorCompanionSetup.exe** from normal File Explorer after closing Word. It contains the MSI and both application components; no adjacent payload folder is needed. `Release.json` deliberately selects application **1.0.0.21**, MSI **1.0.21**, and Atlas baseline `9395e094f87a8718ee430255746f0b841d3f37ba`. The exact clean build SHA must match `package.json` and `-ExpectedSourceCommit` (defaults to HEAD). This is a packaging candidate, not a claim of installed Windows acceptance. Build with existing Windows tooling, without launching Visual Studio: ```powershell .\Build-Setup.ps1 -PackagePath '' ` -ExpectedSourceCommit '' ` -OutputDirectory '' -CertificateThumbprint '' ``` The builder verifies the payload inventory and both VSTO signatures, creates an embedded CAB/MSI with Windows Installer's existing COM API and makecab, and compiles the bootstrapper with the installed .NET Framework compiler. It installs no tools. The existing developer certificate signs the MSI and EXE. A local developer certificate is not a public distribution certificate: normal VSTO trust approval is still required. Setup never writes certificate trust, inclusion lists or security policy. Missing Framework 4.8, VSTO or .NET 10 x64 Windows Desktop prerequisites produce a specific error; they are not installed or repaired automatically. ## Installation contract - Version21 uses ProductCode `{0BF0FC05-40A0-4B6E-B7BC-1FEA9A7C8530}` with the established UpgradeCode. Its transactional older-product range includes both versions 10 through 20; same-version21 uses the existing maintenance path. Version12-specific notes below describe the preserved historical correction. - Before registration/VSTO/MSI changes, setup stops only the exact installed tray executable in this session, holds its existing singleton lock against restart, and checks every existing candidate payload file for replacement access without writing bytes. Locked/read-only/inaccessible files stop setup with their path and Windows error; permissions and installed files are not changed to bypass errors. The guard releases on failure and before launching the upgraded tray. Regression tests use disposable locked/read-only files, never the installed application. This hardens the reported copy-failure path; an actual MSI upgrade, including any transient lock or rollback-security failure, still needs human acceptance. - Per-user MSI, no ALLUSERS property; limited-privilege summary flag, compressed CAB. - `%LOCALAPPDATA%\Programs\PlotDirector Companion` contains VSTO and `Agent`. - Start menu opens the control centre; the current user's Startup shortcut starts the same tray executable without opening its window at Windows sign-in. - Word's manifest points to the installed signed manifest with `|vstolocal` and LoadBehavior 3, preserving the existing registered-DLL hash resolver. - The bootstrapper detects a packaged execution context and launches itself through Win32_Process as the same user in normal Windows before touching installation state. It never treats a private HKCU view as installation proof. - Close Word first. Setup stops only this session's existing Companion agent from LocalAppData; it never terminates Word or Visual Studio. - Existing registration and exact-product VSTA metadata are exported under `%LOCALAPPDATA%\PlotDirector\InstallerBackup\`. - Previous exact PlotDirector VSTO deployments use the supported VSTO uninstaller. Only its `-401` (not installed) result permits removing that exported orphaned PlotDirector VSTA record. Other products and ClickOnce caches are untouched. - Re-running setup uses Windows Installer recaching/repair for this product. - The complete desktop feature is explicitly selected with `ADDLOCAL=Complete`, marked DisallowAdvertise/UIDisallowAbsent, and never inherits old feature states. Version10 can have an advertised MSI feature despite physical version10 files. Migrating that state registered version12 without copying its files; the `Test-UpgradeRegression.ps1` negative control rejects the original faulty MSI. Registered-but-advertised version12 is handled by the same-product repair path. Strict post-install file-version checks remain and now log both detected versions; native feature state must also be Local (3), not Advertised (1). - Version12 has new ProductCode `{0B1E8E22-FCF5-4D9C-99A1-5D0F4BD3210C}` and the same UpgradeCode `{641A087B-9779-458C-B290-BCBBAD49319A}`. Older family products below MSI 1.0.12, including qualified 1.0.10, are major-upgrade candidates; removal is inside the MSI transaction before copying files. A separate detect-only range and launch condition reject newer versions. Same-version12 is a repair. - File/component identifiers derive from target-relative paths; existing component GUIDs remain identical to the qualified version10 MSI. The independent `Test-SetupPackage.ps1` reads the MSI/CAB, verifies every payload hash, component GUID, upgrade boundary, shortcut, sequence and per-user flag without running it. - The bootstrapper queries the native MSI inventory before and after installation, refusing machine/other-user context or newer versions before any mutation. It has an explicit asInvoker execution manifest and uses generated version constants from the same Release.json as the MSI builder. - Windows Settings > Apps > **PlotDirector Companion** uses the MSI uninstall path for the installed files, registration and shortcuts. Existing application state, document metadata, manuscripts and retained backups are not MSI components. - Authentication tokens in version 1.0.0.10 are memory-only. Restarting the agent requires normal Development browser approval again. Document associations remain inside their documents; the installer neither opens nor saves documents. For unattended qualification, do not execute Setup, VSTOInstaller, msiexec, the installed tray or Word. `Inspect-UserInstallation.ps1` uses only read-only supported queries; its local JSON contains personal identity/profile data and must not be published. It does not use Win32_Product, launch applications or change the theme. `Update-WordCompanion.ps1 -NoSync` may build a clean local qualification commit after the caller safely fetches/fast-forwards; it still requires the tracked remote tip to be an ancestor and never reconciles divergent history. This permits validation before publishing a packaging commit. Its single build/test run supplies reusable evidence for both handover prompts, including native-import and Intent assessment. The original version10 installer and `Qualification-2026-11-05.md` are the recovery baseline. Never overwrite that EXE or relabel its payload as version12. Actual upgrade, uninstall/rollback and Word/visual acceptance require the separately authorised manual checklist; static MSI inspection does not qualify those actions. An MSI result of zero is only a packaging result. Acceptance additionally requires normal Word's minimal ribbon, Open Companion activation, connected IPC, exact installed payload hashes/version, tray visibility and a real Word close/reopen. Do not reboot the author's laptop as a test; inspect and launch the installed Startup shortcut and report that actual reboot has not been exercised.